EasyManua.ls Logo

Rinstrum R427 - ED (Dynamic Reading Count-By); MODE (Capture Mode); IN.STRT (Capture Start Input); IN.MID (MID Capture Input)

Rinstrum R427
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual Rev 1.13
Page 82 004R-646-113
0..100 %
Default 40 %
12.10.7. ED (Dynamic reading count-by)
Path Description
AXLE
ED
Count-by setting for dynamic weights.
Values <OPT>
_1_, _2_, _5_
(Default)
, _10_,
_20_, _50_, _100_
12.10.8. MODE (Capture mode)
Path Description
AXLE
MODE
Weighing mode.
Values <OPT>
DYNAMIC
(Default)
, STATIC,
OFF
12.10.9. IN.STRT (Capture start input)
Path Description
AXLE
IN.STRT
input for start of axle, if not set then the min weight
will be used instead. If this input is set then
capturing will start when the input goes high rather
than by the weight.
Values <OPT>
NONE
(Default)
, IO1 .. IO32
12.10.10. IN.MID (Mid capture input)
Path Description
AXLE
IN.MID
input for mid of axle.
Values <OPT>
NONE
(Default)
, IO1 .. IO32
12.10.11. IN.END (End capture input)
Path Description
AXLE
IN.END
input for end of axle, if not set the min weight (minus
hysteresis) is used instead. (end capture input) If
this input is set then capturing will end when the
input goes high rather than by the weight.
Values <OPT>
NONE
(Default)
, IO1 .. IO32
12.10.12. GROUP (Axle group time)
Path Description
AXLE
GROUP
How long to wait for next axle in group, set to 0 for
no groups. If this is set then axle group sub-totals
will calculated. This time sets how long to wait for an
axle before the group is considered finished.
Values <NUM>
0.00 .. 60.00 s
Default 0

Table of Contents

Related product manuals