EasyManua.ls Logo

Rinstrum R427 - Sfn: KEY (Function Key; Remote Input); Sfn: PRINT (Printing Functions)

Rinstrum R427
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual Rev 1.13
004R-646-113 Page 67
12.4.3. SFn: KEY (Function Key / Remote Input)
Path Description
FUNC
└ SFn
KEY
Select front panel key or external input to trigger the
special function. All functions that respond to input
events have a KEY setting.
F1 and F2 are permanently assigned to Truck
and Print functions and cannot be reassigned.
KEY Values <OPT>
None
(Default),
F1 .. F3
IO1 .. IO32
12.4.4. SFn: PRINT (Printing Functions)
Path Description
FUNC
└ SFn
TYPE : PRINT
KEY
PRT.OUT
TOTAL
CLR.ASK
AUTO
IL.TYPE
I.LOCK
Configuration of the PRINT Special Function.
KEY: Select PRINT key using front function key or
external input.
PRT.OUT (PRINT OUT): Selects the printout to
print. Printouts are configured in the PRINT menu.
TOTAL: Sets whether the print key affects the
product totals.
Options are:
ADD: Add to totals
UNDO: Undo last add to totals
CLR.ALL: Clear all totals
CLR.SESS: Clear session total
CLR.ASK (Prompt for Clear): Sets whether the
operator is prompted to confirm the totals clear.
AUTO (Automatic printing): Sets whether printing
occurs automatically.
IL.TYPE (Interlock Type): Sets the type of printing
interlock to be used. Options are:
MOTION: Printing is enabled every time the
scale becomes stable.
I.LOCK: Printing is enabled when the weight
is stable after a weight movement larger than
the interlock weight.
RET.Z: Printing is enabled after the scale has
returned to zero and is stable at a reading
other than zero.
I.LOCK (Interlock): Sets the interlock weight.
KEY Values <OPT>
None
(Default)
, F1 .. F3,
IO1 .. IO32
PRT.OUT Values <OPT>
None
(Default)
,
PRINT.1 .. PRINT.2
TOTAL Values <OPT>
NONE
(Default)
ADD
UNDO
CLR.ALL
CLR.SESS
CLR.ASK Values <OPT>
NO
(Default)
, YES
AUTO Values <OPT>
NO
(Default)
, YES
IL.TYPE Values <OPT>
NONE
(Default)
MOTION
I.LOCK
RET.Z
I.LOCK Values <NUM>
0 .. Fullscale

Table of Contents

Related product manuals