Defines an ID Code that serves as an extension of the access code.
In order to enable communication between the alarm company and the
Installation, the same Remote ID code must be entered into the account profile
in the configuration software.
For successful communication, the ID code along with the access code must
match between the Upload/Download software and the main panel.
Dealers often use the customer's monitoring station account number for the
ID Code, but you can use any 4-digit code unique to the installation
MS Lock is a security function used in conjunction with the configuration
software. It provides greater proprietary security when viewing monitoring
station parameters.
The same 6-digit code, which will be stored in the panel, must be entered into
the corresponding account profile created for the installation in the
Configuration software.
If there is no match between the MS Lock Code defined in the Main Panel and
the MS Lock Code defined in the Configuration software, the Installer will not
have permission to change the following Monitoring Station parameters from
the Configuration software:
MS Lock, Installer Code, MS IP Port, MS IP Address, MS Phone, Default Enable,
MS Account, MS Format, MS Channel, MS Backup, MS Enable, Remote ID,
Access Code.
The call back feature requires the system to call back to a pre-programmed
telephone number to which the alarm company's configuration software
computer is installed. This provides more security for remote operations using
the configuration software.
YES: Call back is enabled
NO: Call back is disabled