Page 50
4. Sirens
5. I/O Expanders
NOTE: This list varies according to the devices that have been allocated to the system.
Only devices that have been allocated can be configured or modified by the
installer.
Zones
The Zones category has the following:
• Parameters
• Alarm (Sequential) Confirmation
• Soak Test
• Zone Crossing
Parameters
Note: The parameters displayed vary according to the type of zones connected to the system.
A label identifies the zone in the system. Up to 16 characters.
The internal ID number of the zone. Each wireless device has its own unique ID
number. Placing ID 00000000000 will delete the zone.
The partition (1 to 3) assignment for each zone.
Each zone can be defined as one of the following types:
Disables a zone. All unused zones should be given this designation.
Used for Exit/Entry doors. Violated Exit/Entry zones do not cause an
intrusion alarm during the Exit/Entry Delay. If the zone is not secured by
the end the delay expires, it will trigger an intrusion alarm.
To start an arming process, this zone should be secured. When system is
armed, this zone starts the entry delay time.