Page 44
System: Controls
Parameter
Default
3 Minute Bypass
NO
YES: Bypasses all zones automatically for 3 minutes when power is restored to an
"unpowered" system.
NO: No bypassing occurs.
Labels
You can rename the labels that identify the system and partitions by changing the default
labels (Partition 1, Partition 2, etc.) to meaningful names / location descriptions, for
example, “Sales Dept, or Master Bedroom.”
Labels that can be renamed:
System: Labels
Parameter
Default
Range
System
G4S
Any 16 characters
Edits the global (system) label
Partition 1/2/3
Partitions 1 through 3
Any 16 characters
Edits partition labels
To rename labels (using the keypad keys to produce characters), see the table below:
Key
Data Sequence
1
1 . , ' ? ! " ( ) @ / : _ + & * #
2
2 a b c A B C
3
3 d e f D E F
4
4 g h i G H I
5
5 j k l J K L
6
6 m n o M N O
7
7 p q r s P Q R S
8
8 t u v T U V
9
9 w x y z W X Y Z
0
0
Use this key to toggle through all the available characters.

Table of Contents