Page 69
Remote Control Parameters 1-Way Key Fob
Parameter
Button 4
Set the operation of button 4 (Large blank button) of the key fob from the following
options:
None: Button disable
Arm: The button is used for Away (Full) arming of the key fob‘s partitions
Stay: The button is used for Stay (Home) arming of the key fob‘s partitions
UO Control (1-20): The button is used to operate a Utility Output
Wireless Two-Way Remote Control Parameters
The Wireless 2-Way Remote Control is an 8-button, rolling code wireless transmitter that is
designed for remote system operation. Having bi-directional functionality enables each
command that is sent to the panel to receive a reply status indication back from the panel
using its multi-color LED and internal buzzer. For higher security, commands can be
defined to be activated with a 4-digit PIN (personal ID number).
Remote Control Parameters 2-Way Remote Control
Parameter
Label
A label identifying the user of the remote control.
Serial Code
The internal ID number of the remote control. Each wireless device has its own unique
serial number. Placing ID 00000000000 will delete the remote control.
Partition
Assign the relevant partitions for the selected remote control.
PIN Code
4-digit PIN code used for higher security when sending commands from the remote
control. The code can be comprised from digits 1,2,3,4.
Note: The use of the PIN code depends on the control Quick UO or system control Quick Arm
Panic Function
Define whether sending panic alarm from the remote control is permitted. If permitted,
pressing on keys and simultaneously for 2 seconds on the remote control
will send a panic alarm.