Page 25
Device Allocation using the Wireless LCD Keypad
RF Allocation Method
Using the RF Allocation method, zones are assigned automatically and
sequentially.
To perform device allocation by RF Allocation:
1. Go to the Installer menu and select Programming Radio Device Allocation
1) RF Allocation. The system immediately goes into Learn mode.
2. Send a transmission from the device. (See Wireless Device RF Transmissions, page 24.)
3. The main panel will acknowledge the transmission with a beep and LCD keypad
displays the device's automatically-assigned zone and index numbers, the device’s
11-digit serial number, and the device’s description.
4. When finished allocating the system device(s), press repeatedly until you arrive
back to Radio Device, then press to Exit, and to confirm.
Serial Number Method
When performing allocation by entering the device’s serial number (“code”),
devices are assigned automatically and sequentially.
To perform device allocation by serial number:
1. Go to the Installer menu and select Programming Radio Device Allocation
2) By Code.
2. Enter the device’s 11-digit serial number (“code”), and then press .
3. The main panel will acknowledge the transmission with a beep and the LCD keypad
displays the device's automatically-assigned zone and index numbers, the device’s 11-
digit serial number, and the device’s description.
4. When finished allocating the system device(s), press repeatedly until you arrive
back to Radio Device, then press to Exit, and to confirm.