Defines whether to generate a tamper message due to input wires shorted
(applicable for shutter only).
Alarm Confirmation
Alarm Confirmation enables to define protection against false alarms and will be used for
alarm verification.
Zones: Alarm Confirmation
Defines which partitions will be defined for alarm sequential confirmation.
Each confirmed partition has a separate timer, which is equivalent to the confirmation
time defined in “Confirmation Time Window”.
A confirmed intruder alarm will be reported if two separate alarm conditions are
detected in the same confirmed partition, during the confirmation time.
Define which zones will be defined for alarm sequential confirmation.
When the first zone goes into alarm the system transmits the first zone alarm. When the
second zone goes into alarm, during the confirmation time, the panel transmits the zone
alarm and the Police code.
Notes:
1. A confirmed zone will be part of the sequential confirmation only if the partition in which the alarm
occurs is defined as confirmed partition as well.
2. Any code can reset a confirmed alarm.
3. If the first zone is violated and not restored until the end of the confirmation time (no second zone
alarm), then this zone will be excluded from the confirmation process until the next arming.
Soak Test
The Soak Test feature is designed to allow false alarming for predefined detectors to be
omitted from the system, while any alarms generated are displayed to the user for
reporting to the monitoring center. This is especially useful if Police response withdrawal
is being threatened and a particular zone is causing unidentified problems.
Each zone can be placed on Soak Test. Any zone placed in the Soak Test list is omitted
from the system for 14 days and is automatically reinstated after that time if NO alarms
have been generated by it.
If a zone in the Soak Test list has an alarm during the 14-day period, the keypad indicates
to the user that the test has failed. After the user looks at the View Fault option, the fault