Use this parameter to define the minimum period between alarm
transmissions (not applicable for shutter termination).
ON: Only one alarm message is transmitted in any 2.5-minute time-period
OFF: Alarm detection is immediately transmitted.
Defines the pulse number threshold for shutter input.
Defines whether to generate a tamper message due to input wires shorted
(applicable for shutter only).
RWX78SU Detector Parameters (for 2 way Shock and Universal detectors)
Defines the LED operation mode.
Yes: Detector's LED activated
No: Detector's LED deactivated
Defines the detector’s level of sensitivity.
Defines whether to enable or disable the universal zone input.
Defines the LED operation mode.
Yes: Detector's LED activated
No: Detector's LED deactivated
Defines the termination of the external zone input.
Define the response time of the external zone input (applicable for NO and
NC terminations only).
Use this parameter to define the minimum period between alarm
transmissions (not applicable for shutter termination).
ON: Only one alarm message is transmitted in any 2.5-minute time-period
OFF: Alarm detection is immediately transmitted.
Defines the pulse number threshold for shutter input.