Page 65
Use this parameter to define the minimum period between alarm
transmissions (not applicable for shutter termination).
ON: Only one alarm message is transmitted in any 2.5-minute time-period
OFF: Alarm detection is immediately transmitted.
Pulses number
2/4/6/8/10/12/14/16
Defines the pulse number threshold for shutter input.
Input Protection
On
On/Off
Defines whether to generate a tamper message due to input wires shorted
(applicable for shutter only).
RWX78SU Detector Parameters (for 2 way Shock and Universal detectors)
Shock
LED Enabled
Yes
Yes/No
Defines the LED operation mode.
Yes: Detector's LED activated
No: Detector's LED deactivated
Shock Sensitivity
TBD
0-100%
Defines the detector’s level of sensitivity.
Universal
Universal
Enabled
Enabled/Disabled
Defines whether to enable or disable the universal zone input.
LED Enabled
Yes
Yes/No
Defines the LED operation mode.
Yes: Detector's LED activated
No: Detector's LED deactivated
External Zone
NO/NC/DEOL/Shutter
Defines the termination of the external zone input.
Response Time
10/500 ms
Define the response time of the external zone input (applicable for NO and
NC terminations only).
Hold On
On
On/Off
Use this parameter to define the minimum period between alarm
transmissions (not applicable for shutter termination).
ON: Only one alarm message is transmitted in any 2.5-minute time-period
OFF: Alarm detection is immediately transmitted.
Pulses number
2/4/6/8/10/12/14/16
Defines the pulse number threshold for shutter input.