Displays the results of the last measurement performed after the last transmission (last
detection or last supervision signal). To receive an updated signal strength, activate the
detector prior to performing the communication test.
For successful communication, the strength of the signal should be higher than the noise
threshold level as measured during calibration of the main panel.
Displays the results of the last battery test performed after the last transmission. OK
message is displayed for a successful test. For an updated value activate the device.
Used to easily test and evaluate the operation of selected zones in your system. It is
recommended to perform walk test after installing all wireless devices and also prior to
performing Testing operation.
The keypad LCD displays the following information:
• Zone number
• TRIP (successful detection)
• TMP (Tamper detection)
• Trbl (low battery)
This menu displays software version of the selected 2-way detector.