Page 113
UO Unit
UO Unit
Parameter
Default
Range
Comm Test
Displays the results of the last measurement performed after the last transmission. To
receive an updated signal strength, activate the UO unit prior to performing the
communication test.
For successful communication, the strength of the signal should be higher than the noise
threshold level as measured during calibration of the main panel.
Battery Test
Displays the results of the last battery test performed after the last transmission. OK
message is displayed for a successful test. For an updated value activate the device.
Version
This menu displays information regarding the UO unit's version.
Activities Menu
The installer can perform special activities on the system via the Activities menu (some of
these activities can also be performed by the user using the LCD keypad.
Activities
Parameter
Default
Range
Main Buzzer On/Off
Used to activate/deactivate the main panel buzzer.
KP Sleep Time
10 seconds 00-60 seconds
Used to set the keypad's Sleep mode time. (The LCD display is turned off.)
Service Mode
Grand masters and Installers can silence any tamper (and suppress a report to the
monitoring station) in the system from the main panel or any accessory for a period
specified in Service Time (see page 34). Use this option, when system accessories require
battery replacement.
Avoid Report Programming
Some protocols have a report code to the monitoring station for entering and exiting the
installer programming. To avoid the entering report and save time, this function
postpones the report for two minutes during which the engineer can enter the
programming menu and no report will be made.