EasyManua.ls Logo

Risco RW332M - Wireless Device RF Transmissions

Risco RW332M
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 24
Wireless Device RF Transmissions
Wireless Device
Transmission procedure
2-Way LCD Keypad
Press and simultaneously for at least 2 seconds
2-Way Panda Keypad
Press and simultaneously for at least 2 seconds.
2-Way Slim Keypad
Press and simultaneously for at least 2 seconds.
PIR Detectors:
PIR
PIR camera
PIR-pet
PIR-pet camera
Press the tamper switch for 3 seconds.
Curtain Detector
After inserting battery, close the bracket and wait 3 seconds.
1-Way magnetic
Contact Detectors
Press the tamper switch for 3 seconds.
2-Way Magnetic
Contacts Detectors
Press the tamper switch for 3 seconds.
NOTE: After programming parameters for this device and
exiting Programming mode, press the Tamper switch for 3
seconds, and then wait 1 minute for the main panel to
download the parameters from the detector.
2-Way Remote
Control
Press and simultaneously for at least 2 seconds
1-Way Keyfob
Click for at least 2 seconds
Wireless 2-Way
Smoke Alarm & Heat
Detector
Press the tamper switch for 3 seconds.
WL 2-Way Indoor
Siren
Press the tamper switch for 3 seconds.
Siren
Press the reset switch on the siren. After a squawk sounds,
within 10 seconds press tamper switch for at least 3 seconds.
2-Button Panic Keyfob
Press both buttons for at least 7 seconds
Wrist Band Panic
Transmitter
Press the button for at least 7 seconds.
When all the devices have been allocated, short-press the LEARN button to exit Learn
mode; the LEDs stop flashing

Table of Contents

Other manuals for Risco RW332M

Related product manuals