Page 108
Testing Menu
The following menu is used to perform tests on the system. Note that each test refers to the
last time the device was activated. Tests can be performed on the following:
1. Main Unit
2. Zone
3. Keyfob
4. Remote Control
5. Siren
6. GSM
7. IP Unit
8. UO Unit
Main Unit
Main Unit
Parameter
Noise Level
This feature establishes the threshold noise level of the main panel (“main unit”)
receiver. The threshold noise level can be established automatically or manually (when
using a keypad).
To establish the main unit receiver's noise level:
Automatic: For automatic calibration select [2] Calibration. After the calibration
process is accomplished, the new noise threshold level is displayed.
Manual: For manual calibration select [1] View/Edit. The value displayed is the
last measured value. Set a new threshold level and press to confirm.
Siren
Activates the main panel siren.
Speaker
Not Applicable
Battery
Displays the battery voltage of the main panel.
Version
Displays the main panel's software version.
Serial Number
Displays the main panel's serial number.