Page 114
Activities
Parameter
Default
Range
Bypass Box Tamper
Provides ability to bypass box tamper condition. When activated and tamper condition
occurs, there will be no alarm, no indication to the Monitoring Station and no record in
the event log.
Note: To enable Bypass Box Tamper, both the Allow Bypass and 24-Hour Bypass parameters must be set
to YES (refer to page 52 and page 55 for more information).
Installer Reset
Use this option to reset an alarm.
Configuration Software Connect
Enables to establish remote communication with the configuration software at a
predefined location through IP or GPRS.
Note: The location of the configuration software should be predefined under
Communication>Configuration Software>IP Gateway
Firmware Update
This option activates a firmware update process. The update can be established through
IP or GPRS. The location of the new firmware should be predefined under Installer
Programming> System>Firmware Update.
1. Once the communication method is selected (IP or GPRS) a special manufacturer
password should be entered. Please refer to your local RISCO branch for this
password.
System Restart
Enables to restart the main panel via the keypad.