Page 126
L.Temp rst Zn=xx
Low temperature alert restored from zone XX defined as a
temperature detector
* Lost Zone=xx
Wireless zone lost, zone no. XX
Low Bat rs Z=xx
Low battery trouble restored from wireless zone no. XX
Low bat. Zn=xx
Low battery trouble from wireless zone no. XX
Low bat.KF=yy
Low battery trouble from wireless remote control XX
* Low Temp. Zn=xx
Low temperature alert from zone XX defined as a temperature
detector
Main:AC restore
AC power restore on main panel
Main: Battery rst
Low battery trouble restore from the main panel
Main: Low AC
Loss of AC power from the main panel
Main: Low battery
Low battery trouble from the main panel
* MS=y call error
Communication fail trouble to MS phone no. Y
* MS=y restore
Communication fail trouble restore to MS phone no. Y
No Com IP card
Communication failure between the WiComm Pro and IP card
* No comm I/O Mdl.
Communication failure between the WiComm Pro and I/O module
* No comm Siren=y
Communication failure between the WiComm Pro and siren Y
* No comm. GSM
No communication between the GSM/GPRS Module and the
WiComm Pro
* Phone fail
If the phone line is cut or the DC level is under 1V
Phone restore
Phone line trouble restore
* Police Keypad=y
Police (panic) alarm from wireless keypad Y
* Police KF=yy
Police (panic) alarm from remote control YY
PTM: Send Data
Load new parameters into the WiComm Pro from PTM accessory
* Radio l.bat S=y
Radio low battery trouble from siren Y
Radio l.bat rS=y
Radio low battery restore from siren Y
* Remote away:P=y
The system has been armed from the configuration software
* Remote program
The system has been programmed from the configuration software
* Remote stay:P=y
The system has been armed in STAY mode from the configuration
software
Restore Zone=xx
Alarm restore in zone no. XX
* RF Jamming
Wireless receiver jamming
Rmt disarm:P=y
Partition Y disarmed from the configuration software
* Siren=y Lost
Siren Y is regarded as lost following supervision test
Siren=y Lost Rst
The WiComm Pro received a signal from siren Y after it has been
regarded as lost
Soak fail Z=xx
Zone XX has failed in the soak test
Special KP=y
Special alarm from the from wireless keypad Y
Spkr l.bat rsS=y
Speaker low battery restore from siren Y
* Spkr low bat S=y
Speaker low battery trouble from siren Y
Start exit P=y
Exit time started in partition Y
* Stay:P=y C=zz
Partition Y Stay Armed (Partial Armed) by user ZZ