System: Timers
Parameter
Default
Range
Specifies how often the system expects to get a signal from the system's transmitters. If a
signal from a zone is not received during the specified time the zone will be regarded as
lost, the system will send a report code to the monitoring station, and the system status
will be "Not Ready".
Notes: 0 hours disables supervision
It is recommended to set the supervision time to a minimum of 3 hours
TX Supervision
015
0-255 min
Specifies how often a bi-directional wireless device generates a supervision request to the
system.
If any of the accessories does not respond to the request at least once during the RX
Supervision time, the system will regard the accessory as lost.
Note: The device will generate the supervision message according to the time defined.
Important: The RX Supervision time should be higher than the TX Supervision time in order to eliminate
false “lost “events.
Redial Wait
30 sec
0-255 sec
The number of seconds between attempts at redialing the same phone number.
Applies to both the MS Retries and FM Retries parameters.
Note: Used for GSM.
More
Swinger Limit Shutdown
00
0-15 times
A swinger is a repeated violation of the same zone, often resulting in a nuisance alarm
and usually due to a malfunction, an environmental problem, or the incorrect
installation of a detector or sensor.
This parameter specifies the number of violations of the same zone reported during a
single armed period, before the zone is automatically bypassed.
Note: 00 to disables the swinger shutdown
No activity
00
0-99 hours
Determines the time limit for reception of signals from sensors used to monitor the
activity of sick, elderly or disabled people. If no signal is received from a zone defined
with the "No Activity" feature at least once within the defined time limit, a “No-
Activity” alert can be send to the Follow Me destination, a local message can be heard,
and a report to monitoring station can be defined to be send.
Options: 0 =this parameter is inactive.
Last Exit Sound
00
0-255 seconds