Measurements
R&S
®
FSW
305User Manual 1173.9411.02 ─ 19
For more information see chapter 5.13.3.4, "Controlling V-Networks (LISN)",
on page 295.
LISN Type................................................................................................................... 305
Phase..........................................................................................................................305
150 kHz Highpass Filter..............................................................................................305
LISN Type
Selects the network type and activates output to the network via the user port of the
R&S FSW. The network type determines the supported phases (see table 5-19).
"Off" disables LISN control and output.
Remote command:
INPut:LISN:TYPE on page 807
Phase
Selects the phase to be measured. Phase N and L1 are included in all four LISN.
Phase L2 and L3 are only included in four-line networks.
You can select one phase only for each measurement.
Remote command:
INPut:LISN:PHASe on page 806
150 kHz Highpass Filter
Enables or disables the use of an additional 150 kHz highpass filter to protect the
R&S FSW LISN from excessive input.