Remote Commands
R&S
®
FSW
754User Manual 1173.9411.02 ─ 19
●
The lower limit of a power class must always be the same as the upper limit of the
previous power class.
● The power class must already exist (see CALCulate:LIMit:ESPectrum<sb>:
PCLass:COUNt on page 751).
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
<class> 1...4
power class
Parameters:
<Level> Range: -200 dBm to 199.9 dBm
Example:
CALC:LIM:ESP:PCL2:MIN -40 dBm
Sets the minimum power value of the second power class to -40
dBm.
Manual operation: See "PMin/PMax" on page 219
11.5.6.7 Configuring MSR SEM Measurements
The following commands configure MSR SEM measurements. For details see chap-
ter 5.6.4.4, "Multi-Standard Radio (MSR) SEM Measurements", on page 205.
For manual operation see chapter 5.6.5.5, "MSR Settings", on page 219.
[SENSe:]ESPectrum<sb>:MSR:APPLy............................................................................ 754
[SENSe:]ESPectrum<sb>:MSR:BAND............................................................................. 755
[SENSe:]ESPectrum<sb>:MSR:BCATegory......................................................................755
[SENSe:]ESPectrum<sb>:MSR:CLAS..............................................................................756
[SENSe:]ESPectrum<sb>:MSR:GSM:CARR.....................................................................757
[SENSe:]ESPectrum<sb>:MSR:GSM:CPResent............................................................... 758
[SENSe:]ESPectrum<sb>:MSR:LTE:CPResent.................................................................758
[SENSe:]ESPectrum<sb>:MSR:MPOWer.........................................................................759
[SENSe:]ESPectrum<sb>:MSR:RFBWidth........................................................................759
[SENSe:]ESPectrum<sb>:MSR:APPLy
This command configures the SEM sweep list according to the MSR settings defined
by previous commands.
Suffix:
<sb>
.
1 | 2 | 3
Sub block in a Multi-SEM measurement
Configuring and Performing Measurements