Remote Commands
R&S
®
FSW
766User Manual 1173.9411.02 ─ 19
[SENSe:]LIST:RANGe<range>:DETector......................................................................... 767
[SENSe:]LIST:RANGe<range>:FILTer:TYPE.................................................................... 768
[SENSe:]LIST:RANGe<range>[:FREQuency]:STARt......................................................... 769
[SENSe:]LIST:RANGe<range>[:FREQuency]:STOP..........................................................769
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation............................................................770
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation:AUTO..................................................770
[SENSe:]LIST:RANGe<range>:INPut:GAIN:STATe........................................................... 770
[SENSe:]LIST:RANGe<range>:INPut:GAIN[:VALue]..........................................................770
[SENSe:]LIST:RANGe<range>:LIMit:STARt......................................................................771
[SENSe:]LIST:RANGe:LIMit:STATe................................................................................. 771
[SENSe:]LIST:RANGe<range>:LIMit:STOP...................................................................... 771
[SENSe:]LIST:RANGe<range>:POINts[:VALue]................................................................ 772
[SENSe:]LIST:RANGe<range>:RLEVel............................................................................ 772
[SENSe:]LIST:RANGe<range>:SWEep:TIME................................................................... 772
[SENSe:]LIST:RANGe<range>:SWEep:TIME:AUTO..........................................................773
[SENSe:]LIST:RANGe<range>:TRANsducer.....................................................................773
[SENSe:]LIST:RANGe<range>:BANDwidth[:RESolution] <RBW>
This command defines the resolution bandwidth for a spurious emission measurement
range.
Suffix:
<range>
.
1..30
Selects the measurement range.
Parameters:
<RBW> Resolution bandwidth.
Refer to the data sheet for available resolution bandwidths.
Default unit: Hz
Manual operation: See "RBW" on page 244
[SENSe:]LIST:RANGe<range>:BANDwidth:VIDeo <VBW>
This command defines the video bandwidth for a spurious emission measurement
range.
Suffix:
<range>
.
1..30
Selects the measurement range.
Parameters:
<VBW> Video bandwidth.
Refer to the data sheet for available video bandwidths.
Default unit: Hz
Manual operation: See "VBW" on page 244
Configuring and Performing Measurements