Remote Commands
R&S
®
FSW
851User Manual 1173.9411.02 ─ 19
11.7.4.1 Configuring the Triggering Conditions
TRIGger[:SEQuence]:DTIMe...........................................................................................851
TRIGger[:SEQuence]:HOLDoff[:TIME]..............................................................................851
TRIGger[:SEQuence]:IFPower:HOLDoff...........................................................................851
TRIGger[:SEQuence]:IFPower:HYSTeresis...................................................................... 852
TRIGger[:SEQuence]:LEVel[:EXTernal<port>].................................................................. 852
TRIGger[:SEQuence]:LEVel:IFPower...............................................................................853
TRIGger[:SEQuence]:LEVel:IQPower.............................................................................. 853
TRIGger[:SEQuence]:LEVel:RFPower..............................................................................853
TRIGger[:SEQuence]:LEVel:VIDeo..................................................................................854
TRIGger[:SEQuence]:SLOPe.......................................................................................... 854
TRIGger[:SEQuence]:SOURce........................................................................................854
TRIGger[:SEQuence]:TIME:RINTerval............................................................................. 855
TRIGger[:SEQuence]:DTIMe <DropoutTime>
Defines the time the input signal must stay below the trigger level before a trigger is
detected again.
Parameters:
<DropoutTime> Dropout time of the trigger.
Range: 0 s to 10.0 s
*RST: 0 s
Manual operation: See "Drop-Out Time" on page 431
TRIGger[:SEQuence]:HOLDoff[:TIME] <Offset>
Defines the time offset between the trigger event and the start of the sweep (data cap-
turing).
A negative offset is possible for time domain measurements.
For the trigger sources "External" or "IF Power", a common input signal is used for both
trigger and gate. Therefore, changes to the gate delay will affect the trigger offset as
well.
Parameters:
<Offset>
For measurements in the frequency domain, the range is 0 s to
30 s.
For measurements in the time domain, the range is the negative
sweep time to 30 s.
*RST: 0 s
Example:
TRIG:HOLD 500us
Manual operation: See "Trigger Offset" on page 431
TRIGger[:SEQuence]:IFPower:HOLDoff <Period>
This command defines the holding time before the next trigger event.
Setting Basic Measurement Parameters