Remote-Control Commands
R&S
®
SMW-K144
225User Manual 1178.8013.02 ─ 06
Example: See Example "Configuring the PUSCH settings" on page 159.
Manual operation: See "TPMI" on page 90
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:MODE <PtrsMode>
Sets if the PTRS configuration is defined, manually (with the ...PDSCH:PTRS:...
commands) or automatically (from the current PDSCH DMRS settings).
Parameters:
<PtrsMode> MANual | AUTO
*RST: MANual
Manual operation: See "Mode" on page 96
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:STATe <PXschPtrsState>
Enables the transmission of phase-tracking reference signals.
Parameters:
<PXschPtrsState> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "State" on page 96
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:TMDen <PtrsTimeDensity>
Sets the parameter time density.
Parameters:
<PtrsTimeDensity> TD1 | TD2 | TD4
*RST: TD1
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "Time Density (L_PTRS)" on page 96
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:REOF <PtrsREOffset>
Sets the parameter resource element offset.
Parameters:
<PtrsREOffset> RE00 | RE01 | RE11 | RE10
*RST: RE00
PDSCH/PUSCH Commands