Remote-Control Commands
R&S
®
SMW-K144
226User Manual 1178.8013.02 ─ 06
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "RE-offset" on page 97
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:FRQDen <PtrsFreqDensity>
Sets the parameter frequency density.
Parameters:
<PtrsFreqDensity> FD2 | FD4
*RST: FD2
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "Frequency Density (K_PTRS)" on page 97
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PDSCh:PTRS:EPRE <EpreRatio>
Sets the parameter EPRE ratio.
Parameters:
<EpreRatio> RAT0 | RAT1
*RST: RAT0
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "EPRE Ratio" on page 97
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>[:CW<s2us0>]:PDSCh|PUSCh:CCODing:IMCS
<ChanCodingIMCS>
Sets the modulation and coding scheme index.
Parameters:
<ChanCodingIMCS> integer
Range: 0 to 28
*RST: 0
Example: See Example "Configuring the PDSCH incl. PTRS settings"
on page 153.
Manual operation: See "I_MCS" on page 93
PDSCH/PUSCH Commands