IIT-2000/2010/5000/5010 Instruction Manual/English
64 05/08/2015 Version No. 001
Note
The FAIL MODE setting only applies to AUTO tests. This
setting is ignored when running MANU tests.
Steps
1. Press the UTILITY key on the front panel when the
tester is in MANU/EDIT status. The display will go
from the normal EDIT status to the MANU Utility
menu for the current test.
UTILITY
L I T Y IM A UN U T 2M A N U = * * * - 0 0
A R C M D E : OO FF
G R O U N D M O D E : NO
P A S S H L D :O O FF
F A I L M D E :O
PS T O
M A X H O L D : O F F
2. Use the UP/DOWN arrow keys to move to the
FAIL MODE setting.
3. Use the scroll wheel to set FAIL MODE.
FAIL MODE
CONTINUE, HOLD, STOP
4. Press the EDIT/SAVE key to save
and exit the MANU Utility menu.
EDIT/SAVE
Note
The ESC key can be pressed at any time in the MANU
Utility menu to cancel and exit.