Whenever you upgrade the master supervisor engine, the slave one 
(if any) is upgraded at the same time to keep the version consistent. 
The upgrade of a line card will upgrade all the line cards inserted 
into the device.Do not power off the device before the upgrade is 
complete. Otherwise, the upgrade program may be lost. 
Before  the  chassis-mount  device  is  upgraded,  you  can  check 
whether  the  software  version  of  all  line  cards  and  supervisor 
engines are consistent with the upgraded object version by the 
show  version  command.  However,  you  cannot  carry  out 
master-slave  switch  (such  as  redundancy  force-switchover). 
Otherwise,  it  will  cause  the  upgrade  failure  and  return  to  the 
original version. 
  Upgrade the chassis-mounted device by the upgrade file: 
1.  Confirm the filename of the upgrade file to be loaded is rgos.bin. 
2.  Download the file to the device by using the copy command. 
3.  If  there  is  a  slave  supervisor  engine  on  the  device,  you  need  to  first  upgrade  the  main 
programs of the master and slave supervisor engines successfully. After upgrading the main 
program successfully, the system prompts: 
Upgrade Slave CM MAIN successful!! 
Upgrade CM MAIN successful!! 
4.  Reset the equipment. 
5.  After reset, the upgrade file will run automatically. The system prompts: 
Installing is in process ...... 
Do not restart your machine before finish !!!!!! 
...... 
6.  After the upgrade operation is completed, the system prompts: 
Installing process finished ...... 
Restart machine operation is permitted now !!!!!! 
7.  After  the  operation  of  the  upgrade  file  is  completed,  the  system  resets  automatically  and 
prompts: 
System restarting, for reason 'Upgrade product !'. 
8.  After reset, the upgrading operation of the supervisor engines is completed. The system will 
load and operate the upgrade pack of boards. Moreover, it prompts informaiton in Steps 5 to 6. 
Instead of the information in Step 7, it prompts: 
System load main program from install package ...... 
Load the main program of the supervisor engine to operate from the upgrade file directly. 
9.  After the main program operates normally, the automatic upgrade function starts. If there is 
the slave supervisor engine or other modules in the chassis-mount device, the system prompts: 
A new card is found in slot [1].  
System is doing version synchronization checking ...... 
Current software version in slot [1] is synchronous. 
System needn't to do version synchronization for this card ...... 
Or, the system prompts: 
System is doing version synchronization checking ...... 
Card in slot [3] need to do version synchronization ...... 
Other Printing Information 
Version synchronization begain ......