Configuration Guide NFPP Configuration
Command
Function
Ruijie# copy running-config
startup-config
Save the configurations.
To restore the global isolated time to the default value, use the no
dhcpv6-guard isolate-period command in the nfpp configuration mode. If the
isolated time has been configured on a port, you can use the no dhcpv6-guard
isolate-period command to remove the port-based isolated time configuration
in the interface configuration mode.
Configuring the monitored time
If the isolated time is 0 (that is no isolation), the serviceview monitor will be
performed to auto-monitor the attacker according to the configured monitored
period, providing the attacker information in the system. If the isolated time is
but not 0, the DHCPv6-guard will perform hardware isolation towards the hosts
using the serviceview monitor.
Command
Function
Ruijie# configure terminal
Enter the global configuration mode.
Ruijie(config)# nfpp
Enter the nfpp configuration mode.
Ruijie(config-nfpp)# dhcpv6-guard
monitor-period seconds
Configure the monitored time,
ranging 180-86400s(one day). The
default value is 600s.
Ruijie(config-nfpp)# end
Return to the privileged EXEC mode.
Ruijie# show nfpp dhcpv6-guard
summary
Show the parameter settings.
Ruijie# copy running-config
startup-config
Save the configurations.
To restore the monitored time to the default value, use the no dhcpv6-guard
monitor-period command in the nfpp configuration mode.