Configuration Guide IP Address and Service Configuration
To set the IP MTU, execute the following command in the interface configuration
mode:
Command
Function
Ruijie(config-if)# ip mtu bytes
Set the MTU in the range 68 to 1500 bytes.
Ruijie(config-if)# no ip mtu
Restore the setting to the default.
Configuring IP Source Routing
Ruijie product supports IP source routing. Upon receiving an IP packet, the
device will check its IP header like strict source route, loose source route and
recorded route, which are defined in RFC 791. If one of these options is enabled,
the device performs appropriate action. Otherwise, it sends an ICMP error
message to the source and then discards the packet. Our product supports IP
source routing by default.
To enable IP source routing, execute the following command in the interface
configuration mode:
Command
Function
Ruijie(config)# ip source-route
Enable IP source routing.
Ruijie(config)# no ip source-route
Disable IP source routing.