Section 4: Expanded Memory Commands
SATO Programming Reference Page 4-13
Special Notes 1. You must have the optional Expanded Memory to use this com-
mand. Call your SATO representative for details.
2. The maximum storage capacity is 999 graphics, up to the capacity
of the memory card used.
3. If a data transmission error occurs, the printer will beep and the
ERROR LED will come on. You must then retransmit the image.
4. Each graphic to be stored must be sent in its own data stream.
Example of correct data stream:
<ESC>A
<ESC>GIHaaabbb001(DATA)
<ESC>Z
<ESC>A
<ESC>GIHaaabbb002(DATA)
<ESC>Z
Example of incorrect data stream:
<ESC>A
<ESC>GIHaaabbb001(DATA)
<ESC>GIHaaabbb002(DATA)
<ESC>Z
5. Do not use ASCII <CR> or <LF> characters (carriage return or line
feed) as line delimiters within the graphic data or the actual image
will not be printed as specified.
6. The graphics storage number (ddd) must be specified with this
command.
7. See Table 1 in Section 1. Programming Concepts for values of
Hmax and Vmax. The number of allowable blocks is determined by
dividing this number by 8