131
ESC+2D50 Datamatrix (ECC200)
Persistence of
the command
When printer is powered off
Set parameter will not be retained
Becomes invalid after execution
Becomes invalid after the job
[Function]
Prints DataMatrix code (ECC200).
[Format] (Setting portion)
<2D50>,aa,bb,ccc,ddd
●Parameter
a [Cell width] = Valid range : 01 to 16 dots
b [Cell height] = Valid range : 01 to 16 dots
c [Number of cell per line] = Valid range : 000 (fixed)
d [Number of line per symbol] = Valid range : 000 (fixed)
[Format] (Data portion)
<DN>mmmm,n~n
●Parameter
m Quantity of data = Valid range : 1 to 3116
n Print data = Data
[Coding Example] Cell width : 3 dots Cell height : 3 dots
<A>
<V>100<H>200<2D50>,03,03,000,000
<DN>0010,0123456789
<Z>
[Notes]
1. In case any other parameters than above are specified, or parameters and quantity of data are not consistent with each other,
the symbol will not be printed correctly.
2. Make sure to leave 2mm margin of each side of the symbol for good scanner-readability.
3. To specify the code address [7EH], write [7EH, 7EH]. Quantity of data is [0002].