23
Modification
Available for
WS4 series
ESC+FW Rule / Grid Print
ESC+FW
Hex code
ESC
FW
Parameter
<1B>
16
<46>
16
<57>
16
Rule aabcccc
Grid aabbVccccHdddd
Default setting
None
Persistence of
the command
When printer is powered off
Set parameter will not be retained
Validity in a job
Becomes invalid after execution
Validity after a job
Becomes invalid after the job
[Function]
Prints rule / grid
[Format]
<FW>aabcccc Rule print
Parameter
a [Line width] = Valid range : 02 to 99 dots
b [Horizontal / vertical setting] = H : Horizontal
V : Vertical
c [Length] = Valid range : Refer to table below
<FW>aabbVccccHdddd Grid print
Parameter
a [Vertical line width] = Valid range : 02 to 99 dots
b [Horizontal line width] = Valid range : 02 to 99 dots
c [Vertical line length] = Valid range : Refer to table below
d [Horizontal line length] = Valid range : Refer to table below
[Coding example] Ruled line: Line width: 4, Horizontal setting, Length: 400
Grid: V. line width: 8, H. line width: 8, V. line length: 300, H. line length: 400
<A>
<V>100<H>200<FW>04H400
<V>300<H>200<FW>0808V300H400
<Q>2
<Z>
[Notes]
1. If the print start position is outside of the printable area, it will not print due to a command error.
[Valid range]
Model
Horizontal line length in dots
Vertical line length in dots
WS408DT/TT
1 to 832
1 to 7992
WS412DT/TT
1 to 1248
1 to 11988