EasyManua.ls Logo

SATO WS4 Series - Understand Your Printer - WS4 Direct Thermal (DT) Model

SATO WS4 Series
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
5. How to Read the Command Manual
7.2 Modification
Available for
WS4 series
ESC+L
Hex code
ESC
L
Parameter
<1B>
16
<4C>
16
aabb
Initial setting
aa=01, bb=01
Persistence of
the command
When printer is powered-off
Set parameter will not be retained
Validity in a job
Parameter set will be retained until next valid setting
Validity after a job
Parameter set will be the initial value for the next job
[Function]
Specifying the print expansion factor.
[Format]
<L>aabb
● Parameter
a [Horizontal expansion factor (width)] = validity range : 01 to 12
b [Vertical expansion factor (height)] = validity range : 01 to 12
[Coding example] Horizontal expansion factor (width): 4, Vertical expansion factor (height): 3
<A>
<V>100<H>200<P>3<L>0403<OA>ABCD
<Q>2
<Z>
[Notes]
1. The pitch between the characters is equally enlarged. When setting the inter character pitch <P>, the preset horizontal
expansion factor <L> will be valid for the inter character pitches <P> thereafter.
2. If enlarging graphics, put in expansion factor <L> just before the graphic print command.
[Tips]
1. When using the expansion function, be careful not to fall out of the printing range. Therefore, select a correct print format.
[Valid command]
WS4 series
Font
<X20>
<X21>
<X22>
<X23>
<X24>
<OA>
<OB>
<K1>
<K2>
<K3>
<K8>
<K9>
<k1>
<k2>
<k3>
<k8>
<k9>
Modification
<P>
<RF>
Graphic
<G>
<GM>
Font Expansion
1)
3)
4)
8)
9)
10)
11)
12)
13)
14)
5)
7)
6)
2)

Table of Contents