190
System
Available for
WS4 series
ESC+IG Sensor Type
ESC+IG
Hex code
ESC
IG
Parameter
<1B>16
<49>16<47>16
a
Default setting
a=0
Persistence of the
command
When printer is powered off
Set parameter will not be retained
Validity in a job
Retained until next valid setting
Validity after a job
Retained until next valid setting
[Function]
Changes sensor type temporarily
[Format]
<IG>a
Parameter
a Sensor type = 0 : Reflective (I-Mark)
1 : Transmissive (Gap)
2 : Sensor off
[Coding Example]
<A>
<IG>0
<Z>
[Notes]
1. The setting by this command is normally not needed.
2. The setting is valid until the printer is powered off and printers internal setting becomes valid after rebooting.