8024484/2019-06-06 • © SICK AG • Subject to change without notice 101
PROFINET IO interface
Module parameters
Name Description
Average Filter
Distance
Selectlterstrengthforthedistancemeasurements.
Value range
• fast:Thedistancevalueisoutputvirtuallyunltered.
• medium:Shortincorrectmeasurementsareltered.
• slow: Incorrect measurements are smoothed out to the
greatest possible extent.
Default value
• medium
Average Filter
Speed
Selectlterstrengthforthespeedmeasuredvalue.
Value range
• fast:Thespeedmeasuredvalueisoutputvirtuallyunltered.
• medium:Shortincorrectmeasurementsareltered.
• slow: Incorrect measurements are smoothed out to the
greatest possible extent.
Default value
• medium
Measuring
Direction
Select measuring direction for the distance.
Value range
• Negative direction [-].
• Positive direction [+]
Default value
• Positive direction [+]
Error Rejection Set time for error suppression. During this time, the old
measured value is output. If, after the set period of time has
elapsed, there has still not been a valid measurement, the
value “0” is output.
Value range
• o
• 50 ms
• 200 ms
Default value
• 200 ms
Heating
threshold [degC]
Switching threshold in degrees Celsius below which the heat-
ing is switched on
Value range
• –10 ... 40 °C
Default value
• –10 °C