8024484/2019-06-06 • © SICK AG • Subject to change without notice 57
Operating the measuring device
8.5.14 “Oset”menu
Inthismenuyoucansetanoset.
The“Oset”menuisaccessedviathefollowingmenupath:
Main menu
Menu Pron more
MFx On (MF1 MF2 →)Oset
Press the
pushbutton.Theosetthatiscurrentlysetisdisplayed.
Requirement for display
“more” menu: “Yes” option
Value Description
Oset Specifytheoset.Theosetisaddedtotheinternallydeter-
minedmeasuredvalue.Theosetisappliedtoalloutputsand
to what is shown on the display.
Ifthe“Preset”functionwasactivated,theosetisoverwritten
by triggering the preset input.
Adjustment range
–600,000 to +300,000 mm
Factory setting
0 [mm]
Table 23: “Oset” menu
8.5.15 “SpecFu” menu
In this menu you can set special functions.
The “SpecFu” menu is accessed via the following menu path:
Main menu
Menu Pron more
MFx On (MF1 MF2 →)Oset SpecFu
Press the
pushbutton to display the “AvgDst” parameter.
You can scroll within the menu using the
and pushbuttons.
Requirement for display
“more” menu: “On” option
Value Description
AvgDst Selectlterdepthforthedistancemeasurementvalues.
Options
Medium
Slow
Fast
Factory setting
Medium