Operation via Ethernet (Ethernet interface)
60 © SICK AG • Subject to change without notice • 8024484/2019-06-06
9 Operation via Ethernet (Ethernet interface)
ThedistancemeasuringdeviceisttedwithtwoEthernetports.Theseare
for communication via PROFINET IO, and for diagnostics and parameteriza-
tion via SOPAS ET. The two interfaces are of equal status and are internally
connected to a switch.
NOTE!
You can download the SOPAS ET conguration program
online at “www.sick.com/dl100”
NOTE!
Parameters congured using Ethernet (SOPAS ET) are
overwritten with the PROFINET IO parameters as soon as
the device is incorporated into a PROFINET network.
9.1 IPnetworkconguration
IPnetworkconguration–
deliveryconguration
The distance measuring device is shipped with the following IP network
conguration:
IP address: 192.168.100.236
IP network mask: 255.255.255.0
Default gateway: 0.0.0.0.
InvalidIPnetworkconguration IfthesystemdetectsaninvalidIPnetworkconguration,thenthedelivery-
statecongurationisused.
9.2 Ethernet parameter list
9.2.1 Device information
“Deviceinformation”eld
Parameters Description
Device type Display of the device type
Read/write access
Read only
Serial number Display of the serial number of the device
Read/write access
Read only
Table 26: “Device information” page – “Device information” eld