PROFINET IO interface
94 © SICK AG • Subject to change without notice • 8024484/2019-06-06
Input values
(continued)
Rel. Adr. Description
1.2 Bit = 1: MF1 is active.
Type
1 bit
1.3 Bit = 1: MF2 is active.
Type
1 bit
1.4 ... 1.6 Reserved
Type
1 bit
1.7 • Bit = 1: Unable to read measured distance or measured
speed value.
Bit = 0: Current measured value is valid.
Type
1 bit
Output values
Rel. Adr. Description
0.1 ... 0.7 Reserved
Type
1 bit
1.0 Bit=1:Switcholaser
Bit = 0: Switch on laser
Type
1 bit
1.1 ... 1.7 Reserved
Type
1 bit
10.3.9 Module 13: “Temp/i1b, Level/i2b, Hrs/i2b”
Type Input module, 5 bytes, consistent
Description The diagnostic data of the device can be read using this module.