8024484/2019-06-06 • © SICK AG • Subject to change without notice 47
Operating the measuring device
8.5.5 “SSI” menu
You can parameterize the “SSI” interface using this menu.
The “SSI” menu is accessed via the following menu path:
Main menu
Menu Pron SSI.
Press the
pushbutton to display the “Coding” parameter.
You can scroll within the menu using the
and pushbuttons.
Parameters Description
Coding Select data format for the “SSI” interface.
For more information on data formats, see Page 110,
Chapter 11.2.
Options
Gray code
Gry24E: 24 bit measured value gray, 1 bit error binary
Gry24: 24 bit measured value gray
Gry25: 25 bit measured value gray
G25DME: 24 bit measured value and 1 bit error, com-
pletely gray coded; compatible with Gray25 for DME3000,
DME4000 and DME5000
G24+8: 24 bit measured value gray, 8 bit error/warnings/
status binary
Binary code
Bin24E: 24 Bit measured value binary, 1 bit error binary
Bin24: 24 bit measured value binary
Bin25: 25 bit measured value binary
B24+8: 24 Bit measured value binary, 8 bit error/warnings/
status binary
Factory setting
Gry24E