8024484/2019-06-06 • © SICK AG • Subject to change without notice 119
Technical data
15.8 Ambient conditions
Electromagnetic compatibility
1)
EN 61000-6-2, EN 61000-6-3
Ambient temperature range Device without heater: –20 … +55 °C
2)
Device with heater: –40 … +55 °C
3)
Storage temperature range –40 °C … +75 °C
Enclosure rating IP65
Eectofairpressure 0.3 ppm/hPa
Eectoftemperature 1 ppm/K
Temperature drift Typically 0.1 mm/K
Maximum traversing speed 15 m/s
Maximum change in acceleration 15 m/s²
Vibration resistance (sine) EN60068-2-6
Noise EN60068-2-64
Shock resistance EN 60086-2-27
1) The device may cause interference if used in a residential environment.
2) A warm-up phase is required for temperatures under –10 °C; typical duration at –20 °C: 20 min at 24 V.
3) For operation < –20 °C, a supply voltage of at least 24 V is required. A warm-up phase is required for temperatures under –10 °C; typical
duration at –40 °C: 35 min at 24 V.
Table 74: Ambient conditions
15.9 Structural design
Dimensions → See Page 116, Chapter 15.1.
Weight • Distance measuring device: 800 g
• Alignment bracket (optional): 800 g
Materials • Housing: Cast aluminum GD-AlSi12Cu1 (3.2982.05)
• Front screen: PMMA
Connections M12, SpeedCon™
Display • 6-digit with a 5 x 7 dot matrix
• Overowsareindicatedbythemaximumvaluethatcanbedisplayed,
-99,999 or 999,999.
Table 75: Structural design