EasyManua.ls Logo

SICK DL100 Pro

SICK DL100 Pro
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8024484/2019-06-06 • © SICK AG • Subject to change without notice 83
PROFINET IO interface
10.3 Module description
10.3.1 Module 1: “Distance /i2w”
Type Input module, 2 words, consistent
Description Thismodulereadsthecurrentdistancevalueaccordingtotheosetand
resolution settings.
Note Iftherewasnovalidmeasuredvalueduetoadevicefault,amissingreec-
tor or contamination, then the value 0 is output for the distance and the
corresponding bits are set in the status bytes.
Input values
Rel. Adr. Description
0 Current distance in selected resolution with regard to the
oset.Dependingontheresolution,adigitcorrespondsto0.1
to 100 mm.
Type
Signed 32-bit number in two´s complement
Module parameters
Name Description
Resolution Determines the resolution of the distance value on the
PROFINET interface. 1 digit can correspond to 0.1 mm,
0.125 mm, 1 mm, 10 mm or 100 mm.
Value range
0.1 mm
0.125 mm
1 mm
10 mm
100 mm
free Distance Resolution [µm]
Default value
0.1 mm
Free distance
resolution
Determines the resolution of the distance value on the
PROFINET interface if the “free Distance Resolution [µm]”
value has been selected in the “Resolution” parameter.
Value range
1 ... 100,000 µm
Default value
100 µm

Table of Contents

Related product manuals