8024484/2019-06-06 • © SICK AG • Subject to change without notice 95
PROFINET IO interface
Input values
Rel. Adr. Description
0 Device temperature [°C]
Type
• Signed 8-bit number in two´s complement
1 Device-specicvalueforthesignalreceptionquality.
Type
• Signed 16-bit number in two´s complement
3 Operating hours in units of 10 hours.
Type
• Signed 16-bit number in two´s complement
10.3.10 Module 20: “MFx”
Type Congurationmodule,noinputandoutputdata
Description ThismoduledenesthebehavioroftheswitchableMF1inputandoutput.
“MFx” module parameter
Name Description
MFx Activate or deactivate switching inputs or switching output.
Value range
• enable
• disable
Default value
• Disable
“MF1” module parameter
Name Description
MF1 Function Select function for MF1 input and output.
Value range
• [Module] Distance Threshold: Output is switched when the
distance from by module parameter “[MF1 Distance] thresh-
old” has been overwritten.
• [Output] Speed Threshold: Output is switched when the
speed limit from module parameter “[MF1 Speed] thresh-
old”hasbeenoverwritten.Thedirectionisdenedinmod-
ule parameter “[MF1 Speed] mode”.
• [Output] Service: The output switches when at least one of
the switched-on service bits has been set.
• [Input]LaserO:Measurementlaserisdeactivatedviathe
input.
• [Input] Preset Static: “Preset Static” function activated via
the input.
Default value
• [Output] Distance Threshold