8024484/2019-06-06 • © SICK AG • Subject to change without notice 53
Operating the measuring device
8.5.11 “MF1 – Srvice” submenu
InthissubmenuyoucanconguretheMF1multifunctionaloutputasa
serviceoutput.Youcanactivate(On)ordeactivate(O)multipleoptions.
The “Srvice” sub-menu is accessed via the following menu path:
Main menu →
→ Menu → →Pron→ → more → →
MFx On → → MF1 → → ActSta → → Functn → → Srvice
Requirements for display
• “more” menu: “Yes” option
• “MFx On” menu: “Enable” option
• “Functn” parameter: “Srvice” option
Parameters Description
WrnLsr Activates or deactivates the warning message when the aging
of the laser means that the measuring device is nearly due to
be replaced.
Options
• On
• O
Factory setting
• On
WrnLvl Activates or deactivates the warning message when the atten-
uation value is not reached, e.g., due to contamination.
Options
• On
• O
Factory setting
• On
WrnTemp Activates or deactivates the warning message when the
internal temperature of the measuring device is outside the
permissible limits.
Options
• On
• O
Factory setting
• On
WrnPlb Activates or deactivates the warning message when the mea-
sured value is implausible. This may be caused by an errone-
ous measured value, obstruction of the light beam, optical
interference, or electrical interference.
Options
• On
• O
Factory setting
• On