8024484/2019-06-06 • © SICK AG • Subject to change without notice 59
Operating the measuring device
“SpecFu” menu
(cont.)
Parameters Description
FMode Requirement for display
• Only for DL100-xxxBxxxx variants with frequency changeover
Select the frequency range. Frequency changeover may
be necessary in cases of multiple distance measuring
devices being arranged in parallel. → See also Page 28,
Chapter 6.4.
Options
• Mode 1
• Mode 2
• Mode 3
Factory setting
• Mode 1
Reset
Perform a reset.
→ See Page 59, Chapter 8.6.
Table 25: “SpecFu” menu
8.6 Performing a reset
1. Select the “Reset” parameter in the “SpecFu” menu.
→ See Page 57, Chapter 8.5.15.
2. Press the
pushbutton.
3. Theconrmationprompt“Sure?”appears.
4. Press the
pushbutton to reset the measuring device to its initial
state. Press the pushbutton to cancel the process.