“SpecFu” menu
(cont.)
Parameters Description
AvgSpd Selectlterdepthforthemeasuredspeedvalues.
Options
• Medium
• Slow
• Fast
Factory setting
• Medium
MsrDir Deningthemeasuringdirection:
If the measuring direction is positive “+”, the distance output
value is equal to the internal distance value measured by the
measuring module. If the measuring direction is negative “-”,
the internal distance value is multiplied by a factor of “–1”.
Thechangeindirectionaectsboththeoutputvalueforthe
distance and the output value for the speed.
Options
• +
• –
Factory setting
• +
ErrRej Select time for error suppression. During this time, the old
measured value is output. If there is still no valid measured
value once the time selected for the parameter “ErrRej” has
elapsed the value “0” is output.
Options
• 200 ms: The error/warning is reported when the error is
indicated for longer than 200 ms.
• 50 ms: The error/warning is reported when the error is indi-
cated for longer than 50 ms.
• O:Theerror/warningisreportedimmediatelyandwithout
delay.
Factory setting
• 200 ms
Heat Requirement for display
• Only for DL100-xxHxxxxx variants with heating
In this menu you can set the temperature at which the heating
turnson.Thehysteresisisxedat2K.
Adjustment range
• –10 … +40 °C
Factory setting
• –10 °C
Table 24: “SpecFu” menu