Operating the measuring device
54 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“MF1 – Srvice” submenu
(cont.)
Parameters Description
NotRdy Activates or deactivates the warning message when the laser
is not ready for operation. This may be due to a hardware error
oritmaybebecausethelaserisswitchedo.Thiswarning
message is also issued during initialization.
Options
On
O
Factory setting
On
Heat Activates or deactivates the warning message when the
heating is switched on. This parameter is only displayed on
measuring devices with the “Heating” option.
Options
On
O
Factory setting
On
Table 20: “MF1 – Srvice” submenu
8.5.12 “Preset” submenu – move to initialization position
Description The “Preset” function enables automated initialization of storage and
retrieval systems and other rail vehicles in case of maintenance, commis-
sioning, or replacement.
Duringinitialization,thedesiredoutputvalueisset(preset)atadened
position (initialization position).
InthissubmenuyoucanconguretheMF1multifunctionalinputforthe
preset function.
NOTE!
When activating the “Preset”, the output of measured
values of the distance measuring device will be temporar-
ily unavailable. We recommend carrying out the “Preset”
while the machine is at a standstill or running at very
low speeds. The maximum activation number is typically
around 10,000 cycles.