Operation via Ethernet (Ethernet interface)
64 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“Diagnostic data” page
(continued)
Field Description
Temperature Display of the current internal device temperature
Read/write access
Read only
Unit
°C
Operating hours Display of the current operating hours
Read/write access
Read only
Unit
h
Table 35: “Diagnostic data” page
9.2.5 Parameter settings
NOTE!
Parameter changes will only take eect permanently if
they are stored using the “Save” button.
“Generalsettings”eld
Parameters Description
Distanceoset Specifyosetvalueforthedistancemeasurementvalue.
Read/write access
Read and write
Input value
–600,000 ... 300,000
Unit
mm
Factory setting
0
Preset Specify preset value for the distance measurement value.
Read/write access
Read and write
Input value
–300,000 ... 300,000
Unit
mm
Factory setting
0
Table 36: “Parameter settings” page – “General settings” eld