Operating the measuring device
56 © SICK AG • Subject to change without notice • 8024484/2019-06-06
8.5.13 “MF2” menu
InthismenuanditssubmenusyoucanconguretheMF2multifunctional
output.
The “MF2” menu is accessed via the following menu path:
Main menu →
→ Menu → →Pron→ → more → →
MFx On → → MF1 → → MF2
Press the
pushbutton to display the “ActSta” parameter.
You can scroll within the menu using the
and pushbuttons. Press
the pushbutton to display the relevant parameter value.
Requirement for display
• “more” menu: “Yes” option
• “MFx On” menu: “Enable” option
Parameters Description
ActSta Selects the level of the MF2 multifunctional output.
Options
• ActLow: LOW level with active output (NC – normally closed)
• ActHi: HIGH level with active output (NO – normally open)
Factory setting
• ActLow
Functn Select function for multifunctional output. The corresponding
submenu for the chosen function is selected.
Options
• Dist
• Srvice
• Speed
Factory setting
• Srvice
Dist/Speed/
Srvice
The corresponding submenu is displayed depending on the
function selected for the “Functn” parameter. See the relevant
table for the parameter description.
Count Counts the switching events of the multifunctional output.
You can reset the counter by switching the distance measuring
deviceoandonagain.
Table 22: “MF2”
menu
“MF2 – Srvice” submenu This submenu corresponds to the “Srvice” submenu in the “MF1” menu.
→ See Page 54, Table 20.
“MF2 – Dist” submenu This submenu corresponds to the “Dist” submenu in the “MF1” menu.
→ Page 51, Table 18.
“MF2 – Speed” submenu This submenu corresponds to the “Speed” submenu in the “MF1” menu.
→ See Page 52, Table 19.