8024484/2019-06-06 • © SICK AG • Subject to change without notice 51
Operating the measuring device
8.5.9 “MF1 – Dist” submenu
InthissubmenuyoucanconguretheMF1multifunctionaloutputasa
distance switch output.
The “Dist” sub-menu is accessed via the following menu path:
Main menu
Menu Pron more
MFx On MF1 ActSta Functn Dist
Requirements for display
“more” menu: “Yes” option
“MFx On” menu: “Enable” option
“Functn” function: “Dist” option
Parameters Description
Limit Sets the distance-based switching threshold
Hysteresis Sets hysteresis for the switching threshold
Table 18: “MF1 – Dist” submenu
inactiv
e
active
Limit
Hyst
Dist
.
Fig. 26: Representation of the “Dist.” function
Limit: Distance-based switching threshold
Hyst: Hysteresis for switching threshold
Dist: Measured distance