8024484/2019-06-06 • © SICK AG • Subject to change without notice 75
PROFINET IO interface
10.1.1 Generic station description (GSD)
A generic station description (GSD) contains a description of the properties
of a PROFINET IO device, e.g., the data transmission rate supported by the
device or the digital information the PLC receives from the device and the
formatofthisinformation.BitmaplesarealsoGSDles.Thestatusofthe
PROFINETIOdeviceisvisualizedusingtheseles.
The generic station description as well as the respective bitmaps are need-
ed to plan a PROFINET IO network. Every device receives an ID number
from the PROFINET IO user organization (PNO).
Name of the
device
ID no. GSD
1)
Bitmaps
DL100-HF 5,800 (hex) GSDML_V2.33-
SICK-DL100HF-
<date>.xml
GSDML_0101_1_
DL100.bmp
1) Example:Foralepublishedon3/15/2019,thelenameis
GSDML-V2.33-SICK-DL100HF-20190315.xml
Table 54: DL100 Pro distance measuring device generic station description
NOTE!
You can download the GSD le for the DL100 Pro dis-
tance measuring device at www.sick.com/dl100.
Please note that the GSD le for the DL100 Pro
PROFINET IO / SSI variant is not compatible with the
DL100-2xxxx2112 device variants, which are also
available.
10.1.2 Reading in generic station description (GSD)
BeforeyoucancongurePROFINETIOfortheDL100ProPROFINETIOfor
thersttime,youwillhavetoloadthegenericstationdescriptionofthe
DL100 Pro into the hardware catalog of the network engineering tool (e.g.,
TIA-Manager from Siemens).
1. DownloadtheGSDlefromthewww.sick.com/dl100webpage.
2. Follow the instructions in the online help or in the user manual of the
network engineering tool in order to read in the generic station descrip-
tion.
The hardware catalogue is displayed in the network engineering tool.
YoucanuseaPROFINETIOnetworkengineeringtooltocongurethe
distance measuring device for your application. You will need the generic
station description (GSD) to do so.