8024484/2019-06-06 • © SICK AG • Subject to change without notice 65
Operation via Ethernet (Ethernet interface)
“Resolutionmeasuredvalue”eld
Parameters Description
Distance
resolution
Select resolution for the “distance” output value. The mea-
sured value is multiplied by the resolution. The parameter
doesnothaveanyinuenceonthemeasuredvalueshownon
the display.
Read/write access
• Read and write
Input value
• 0: 0.1 / 1: 0.125 / 2: 1.0 / 3: 10.0 / 4: 100.0 / 5: freRes
Factory setting
• 0.1 mm
Speed
resolution
Select resolution for the “speed” output value. The measured
value is multiplied by the resolution. The parameter does
nothaveanyinuenceonthemeasuredvalueshownonthe
display.
Read/write access
• Read and write
Input value
• 0: 0.1 / 1: 1.0 / 2: 10.0 / 3: 100.0 / 4: freRes
Factory setting
• 1 mm/s
Table 37: “Parameter settings” page – “Resolution measured value” eld
“PROFINETIOconguration”eld
Parameters Description
StName Station name display
Read/write access
• Read only
Factory setting
• dl100hf
Table 38: “Parameter settings” page – “PROFINET IO conguration” eld
“SSIconguration”eld
Parameters Description
Protocol Select protocol (data format) for the “SSI” interface.
→ For more information on data formats, see Page 110,
Chapter 11.2.
Read/write access
• Read and write
Input value
• 0: 24 bit binary / 1: 25 bit binary / 2: 24 bit binary + Error
(binary) / 3: 24 bit binary +8 Bit binary / 4: 24 bit gray /
5: 25 bit gray / 6: 24 bit gray + Error (binary) / 7: 24 bit gray
+ Error (gray) / 8: 24 bit gray +8 Bit binary
Factory setting
• 24 bit gray + Error (binary)
Activate SSI
conguration
• Activatetheselectedprotocolusingthe“ActivateSSIcong-
uration” button.
Table 39: “Parameter settings” page – “SSI conguration” eld