Operation via Ethernet (Ethernet interface)
66 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“MF1/MF2activation”eld
Parameters Description
MF activation Activates or deactivates the MF1 multifunctional input and
output and MF2 multifunctional output.
Read/write access
• Read and write
Input value
• 0:O/1:On
Factory setting
• o
Table 40: “Parameter settings” page – “MF1 / MF2 activation” eld
“SettingMF1function”eld Requirement for display
• “MF1 activation” parameter: “On” option
Parameters Description
Function Select function for MF1 multifunctional input and output.
Read/write access
• Read and write
Input value
• 0: Distance: → See Page 67, “MF1, distance undercut
switchingthreshold”eld
• 1: Speed: → See Page 68, “MF1, speed undercut
switchingthreshold”eld
• 2: Service: → See Page 68, “MF1, speed monitoring
conguration”eld
• 3: Laser
• 4: Preset
Factory setting
• Distance
Active state Select the level for the active state for the MF1 multifunctional
input and output.
Read/write access
• Read and write
Input value
• 0: high / 1: low
Factory setting
• low
Table 41: “Parameter settings” page – “Setting MF1 functions” eld