Operation via Ethernet (Ethernet interface)
68 © SICK AG • Subject to change without notice • 8024484/2019-06-06
“MF1, speed undercut switching
threshold”eld
(continued)
Parameters Description
Distance
change
Select the direction of motion to be monitored.
Read/write access
• Read and write
Input value
• 0: Increasing (positive values) / 1: Decreasing (negative
values) / 2: Increasing and decreasing
Factory setting
• Increasing and decreasing
Table 43: “Parameter settings” page – “MF1 speed undercut switching threshold”
eld
“MF1,devicemonitoringcongura-
tion”eld
Requirement for display
• “MF1 activation” parameter: “On” option
• “Function” parameter: “Service” option
Parameters Description
Device monitor-
ingconguration
Activate or deactivate warning messages. If the warning mes-
sage event occurs, the MF1 multifunctional output switches.
Read/write access
• Read and write
Input value
You can activate several warning messages at the same time.
• Measurement stability warning
• Received signal level
• Warning Laser
• Warning temperature
• Device not ready
• Heater status (for device variant with heater)
Factory setting
• The “measurement stability”, “received signal level”, “laser”,
“temperature”, “device not ready for operation” warning
messages are not activated. The “Heater status” message is
deactivated.
Table 44: “Parameter settings” page – “MF1 device monitoring conguration”
eld